ITC Operating mode
5.5 Assigning device parameters
ITC V3, ITC V3 PRO
100 Operating Instructions, 03/2024, A5E42761061-AF
If "Reconnect automatically" is selected, the device continually attempts to restore a
physically interrupted connection to the server. This procedure can be aborted by closing
the connection via the taskbar.
Note
Only one user with RDP on Windows operating system
If a second client has established the same RDP connection to the server with the identical
logon information, the client
-server connection of the first client is interrupted. Even if
"Reconnect automatically" is enabled, the device does not try to re
-establish the
connection to prevent a ping
-pong effect between the clients.
Note
Re
-establish RDP connection after a server restart
If "Reconnect automatically" is activated for an RDP connection and the server has to be
restarted, proceed as follows:
1.
Restart the server.
2.
Re-establish the RDP connection.
Note
Timeout of the function "Reconnect automatically" for an RDP connection
The function "Reconnect automatically" for an RDP connection attempts to re
-
establish the
connection for a period of about 15
seconds. If this is not possible, the function
"Reconnect automatically" is canceled.
If you select the "Connect USB as drive" option (RDP only), you can access a USB memory
device connected to the Industrial Thin Client on the touch screen. The USB data are
transferred to the server and displayed there in Windows Explorer for the devices. For
additional information, see section "Use USB memory devices (Page 125)".
Note
Security threat to the system
The USB may infect the server with viruses, Trojans, spam, etc.
Use a suitable virus scanner to check the data on the USB memory device, or deselect the
"Connect USB as drive" option.
Non
-supported operating systems
The "Connect USB as drive" function is currently not supported for the following operating
systems of the connection partner:
Windows Server 2012, 64-bit
If "Automatic scaling" (only with connection types "Sm@rtServer" and "VNC") or "Full
screen" (only with connection type "Web") is enabled, then the Industrial Thin Client scales
the server screen to its own display size.