System description
SIMOCODE pro
1-106 GWA 4NEB 631 6050-22 DS 03
1.7.8 Configuration information for using an operator panel with display and/or
a decoupling module
If a decoupling module and/or an operator panel with display is to be used in
the SIMOCODE pro system, the following configuration information
regarding the type and number of expansion modules must be observed.
The following tables show the maximum expansion with expansion modules
for the various combinations
(x = possible, – = not possible):
Maximum expansion with expansion modules
1) No bistable relay outputs and a maximum of 5 of the 7 relay outputs are simultaneously
active (> 3 s)
2) No bistable relay outputs and a maximum of 3 of the 5 relay outputs are simultaneously
active (> 3 s)
3) Analog module output is not being used
Table 1-26: Maximum expansion with expansion modules when using an operator panel with display, a current/
voltage measuring module and a decoupling module for SIMOCODE pro V basic units with 24 V DC or
110-240 V AC/DC
SIMOCODE pro basic unit
U
s
= 24 V DC
SIMOCODE pro basic unit
U
s
= 110-240 V AC/DC
Operator panel
Measurement
Decoupling module
Digital module/DM-F
Digital module
Analog module
Temperature module
Earth-fault module
Digital module/DM-F
Digital module
Analog module
Temperature module
Earth-fault module
None/
Operator panel
I-✓ ✓✓✓✓✓ ✓✓✓✓
U/I - ✓ ✓✓✓✓✓ ✓✓✓✓
U/I X ✓
1)
✓
1)
✓✓✓✓ ✓ - ✓✓
✓
1)
✓
1)
✓✓ -
✓ - ✓✓ -
✓ - ✓ - ✓
Operator panel
with display
I - Max. 4 modules Max. 4 modules
U/I - Max. 4 modules Max. 3 modules
--✓✓ -
U/I X ✓ - ✓✓✓✓
2)
- ✓✓✓
✓✓- ✓✓✓ ✓ ---
✓
1)
✓
1)
✓
3)
--
✓ --✓✓