Tables
SIMOCODE pro
A-14 GWA 4NEB 631 6050-22 DS 03
A.5 Detailed messages of the slave diagnostics
The following table contains the detailed messages of the slave diagnostics
for status information and the process alarm. This information is also
contained in data record 92.
Byte.Bit Status information Information
0.0 Trip - Controlling Trip - Execution ON command BU1 BU2
0.1 Trip - Execution STOP command BU1 BU2
0.2 Trip - FB ON BU1 BU2
0.3 Trip - FB OFF BU1 BU2
0.4 Trip - Stalled positioner BU1 BU2
0.5 Trip - Double 0 BU1 BU2
0.6 Trip - Double 1 BU1 BU2
0.7 Trip - End position BU1 BU2
1.0 Trip - Antivalence BU1 BU2
1.1 Trip - Cold starting (TPF) fault BU1 BU2
1.2 Trip - UVO fault BU2
1.3 Trip - OPO fault BU2
1.4 Reserved
2.0 Reserved
2.1 Trip - Protection Trip - Unbalance IM UM
2.2 Trip - Overload IM UM
2.3 Trip - Overload + phase failure IM UM
2.4 Trip - Int. earth fault IM UM
2.5 Trip - Ext. earth fault EM
2.6 Reserved
2.7 Trip - Thermistor overload Th
3.0 Trip - Thermistor short circuit Th
3.1 Trip - Thermistor open circuit Th
3.2 Reserved
3.3 Trip - TM tripping T> TM
3.4 Trip - TM sensor fault TM
3.5 Trip - TM out of range TM
3.6 Reserved
4.0 Trips -
Level monitoring
Trip - Trip I> IM UM
4.1 Trip - Trip I< IM UM
4.2 Trip - Trip P> UM
4.3 Trip - Trip P< UM
4.4 Trip - Trip cos phi< UM
4.5 Trip - Trip U< UM
4.6 Trip - Trip 0/4-20 mA> AM
4.7 Trip - Trip 0/4-20 mA< AM
5.0 Trip - Stalled rotor IM UM
5.1 Reserved
Table A-5: Detailed messages of the slave diagnostics

Table of Contents

Other manuals for Siemens SIMOCODE pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?

Siemens SIMOCODE pro Specifications

General IconGeneral
Protection ClassIP20
Mounting TypeDIN rail mounting
Rated Operational Voltage24 V DC
Rated CurrentUp to 820 A
Protection FunctionsOverload, short-circuit, phase failure, asymmetry, ground fault, motor stall
Operating Temperature Range-25°C to +60°C
Communication ProtocolsPROFIBUS DP, PROFINET, Modbus RTU
Analog OutputsUp to 2
Temperature MonitoringPTC/KTY, RTD (PT100/PT1000)
Digital OutputsRelay outputs, Solid-state outputs
Analog Inputs0/4-20mA, PT100/PT1000

Related product manuals