SIMOCODE pro
GWA 4NEB 631 6050-22 DS 03
Glossary-7
EMERGENCY STOP
Stop in an emergency according EN 418 (ISO 13850).
Operation intended to stop a dangerous process or
movement as quickly as possible in an emergency.
EMERGENCY-STOP command device
Contact block (EMERGENCY STOP mushroom pushbutton
according to EN 418 (ISO 13850), cable-operated switch with
positive opening contacts according to EN 60204-1) that
causes the process, machine or plant to be stopped when
actuated in hazardous situations. This must have positively-
opening contacts, be easy to reach and be tamper-proof.
EMERGENCY-STOP device
A protective device for initiating the appropriate procedure in
an emergency according to EN 418 (ISO 13850) and
EN 60204-1
Enabling circuit
An enabling circuit generates a safety-oriented output signal.
To the outside enabling circuits function as NO contacts
(from the functional perspective safety-oriented opening is
always considered). A single enabling circuit that is designed
to be internally redundant in the safety relay (two-channel)
can be implemented for Category 3/4 according to EN_954-
1 (EN ISO 13849-1:2006).
European norm EXplosion safe (EEx)
European norm EXplosion safe: Specifies the protection
classes for categorizing motors for use in hazardous areas.
Expansion modules
Expansion modules are intended as optional additions for the
SIMOCODE pro V device series. The following expansion
modules are available:
Digital module (DM)
Analog module (AM)
Earth-fault module (EM)
Temperature module (TM).
All expansion modules have the same design with an
enclosure width of 22.5 mm. They are equipped with 2
system interfaces (incoming/outgoing) and removable
terminals.
Factory settings
The factory settings are used to reset all parameters of a
device to the default settings to which they were set at the
factory.
The factory settings can be restored using the "TEST/RESET"
button on the basic unit or via the SIMOCODE ES software.

Table of Contents

Other manuals for Siemens SIMOCODE pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?

Siemens SIMOCODE pro Specifications

General IconGeneral
Protection ClassIP20
Mounting TypeDIN rail mounting
Rated Operational Voltage24 V DC
Rated CurrentUp to 820 A
Protection FunctionsOverload, short-circuit, phase failure, asymmetry, ground fault, motor stall
Operating Temperature Range-25°C to +60°C
Communication ProtocolsPROFIBUS DP, PROFINET, Modbus RTU
Analog OutputsUp to 2
Temperature MonitoringPTC/KTY, RTD (PT100/PT1000)
Digital OutputsRelay outputs, Solid-state outputs
Analog Inputs0/4-20mA, PT100/PT1000