Line Modules Booksize
4.5 Active Line Modules with cold plate
Booksize Power Units
208 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Cold plate
6SL3136-
7TE
21-6AA.
23-6AA.
25-5AA.
25-5AA3 +
Active
Interface
Module
28-0AA.
31-2AA.
Power factor
cos φ
1
1
1
1
1
1
Circuit breaker
(IEC 60947 and UL)
See Chapter Overcurrent protection using fuses and circuit breakers
(Page 51)
Rated short-circuit
-
current
SCCR
4)
kA 65 65 65 65 65 65
Max. total cable length
5)
See Chapter Combination options, Line Modules with line reactors and line
filters (Page 135)
Max. permissible heat sink
temperature
° C 70 73 83 83 75 80
Weight
kg
6.1
10.2
13.8
13.8
20.3
20.4
1)
Derating must be applied due to the transfer of heat to the external heat sink. At a temperature of 40° C at the interface
to the power unit, 80% derating occurs for 6SL3136-7TE28-0AA. and 70 % for 6SL3136-7TE31-2AA.
2)
The specified power ratings apply to the line voltage range from 380 V to 480 V.
3)
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
4)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker and the Line
Module in the drive system.
5)
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module
Note
New systems with 8
0 kW and 120 kW Active Line Modules should ideally be designed with
120
kW Active Line Modules Liquid Cooled in order to avoid power derating.