DC link components
8.3 Braking Module Booksize Compact
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
507
8.3.3.5
DIP switch
The 4-pin DIP switch is located at the top of the Braking Module and sets the braking resistor
being used, the cooling method, and the line voltage.
Make the required settings before the Braking Module is mounted in the control cabinet;
once the module is mounted, the DIP switch can no longer be accessed from the front.
Table 8- 12 DIP switch for Braking Module Booksize Compact
Switch
Switch position
Function
Factory set-
ting
1
ON
Braking resistor without a thermostatic switch
OFF
OFF
Braking resistor with a thermostatic switch
2
ON
Cold plate cooling
OFF
OFF Internal air cooling
3
ON
200 V line voltage
OFF
OFF
400 V line voltage
4
ON
Reserved
OFF
OFF
Note
Terminal assignment for "Braking resistor without a thermostatic switch" mode
For "braking resistor without a thermostatic switch" mode (switch 1 = ON) , terminals X22.1
and X22.2 must
not be assigned for the Braking Module to work.