Motor Modules Booksize
6.4 Motor Modules with cold plate
Booksize Power Units
440 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Note
Disturbance of the 18 A Single Motor Module with 300% overload during operation on a
16 kW Line Module
The maximum output of a 16
kW Line Module is not sufficient for the operation of an 18 A
Single Motor Module with 3
00% overload.
Do NOT operate an 18 A Single Motor Module with a 16 kW Line Module with 300%
overload (i.e. only operate an 18 A Single Motor Module with a 16 kW Line Module, if the
maximum current is limited to 2 x I
rated
).
Use at least a 36 kW Active Line Module or Smart Line Module for operation with 300%
overload.
Double Motor Modules (300% overload)
Table 6- 46 Technical data Double Motor Modules (2 x 3 to 2 x 9 A) with 300% overload
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
) 40%
A
AC
A
A
AC
2 x 2.6
2 x 3.5
2 x 4.3
2 x 6
2 x 7.7
2 x 10
AC
DC-link voltage (up to 2000 m above sea level)
DC
Overvoltage trip
1)
V
DC
DC
820 ± 2 %
Electronics current drawn
at 24 VDC
DC
Current carrying capacity
DC-link busbar
Reinforced DC-link busbars
A
DC
A
DC
DC
100
150
100
150
100
150
2)
Based on I
n
(600 VDC; 4 kHz)
kW
2 x 1.6
2 x 2.7
2 x 4.8
(including electronics losses, see Power loss
W 91.6 126.6 181.6
without derating
kHz
4
Max. permissible heat sink temperature