EasyManua.ls Logo

Siemens SINAMICS S120 - Motor Modules Liquid Cooled; Description

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
Booksize Power Units
444 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Dimensioning notes:
A current derating is only applicable for output frequencies < 10 Hz.
Current derating should be taken into account if the percentage time of operation at
frequencies < 10 Hz is more than 2 % of the daily total operating time.
Also during load cycles, the current specified here must not be exceeded.
When quickly passing through frequencies 0 to 10 Hz, derating does not have to be taken
into account (e.g. for positioning applications).
Note
Information about derating the output current as a function of the ambient temperature and
installation altitude is provided in Chapter "
System data (Page 46)".
6.5
Motor Modules Liquid Cooled
6.5.1
Description
A Motor Module is a power unit (inverter) that provides the power for the connected motor or
motors. Power is supplied by the DC link of the drive unit. A Motor Module must be
connected to a Control Unit via DRIVE-CLiQ. The open-loop and closed-loop control
functions for the Motor Module are stored in the Control Unit.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals