EasyManua.ls Logo

Siemens SINAMICS S120 - Technical Data; Single Motor Modules

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Modules Booksize
6.2 Motor Modules with internal air cooling
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
369
6.2.7
Technical data
6.2.7.1
Single Motor Modules
Table 6- 11 Technical data Single Motor Modules Booksize (3 to 30 A)
Internal air cooling
6SL3120
1TE13-
0AA.
1)
1TE15-
0AA.
1)
1TE21
0AA.
1)
1TE21
8AA.
1)
1TE23-
0AA.
Output current
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40 %
Peak current (l
max
)
A
AC
A
A
AC
A
AC
3
2.6
3.5
6
5
4.3
6
10
9
7.7
10
18
18
15.3
24
36
30
25.5
40
56
Output voltage
V
AC
0 … 0.717 x DC-link voltage
DC link current I
d rated
A
DC
3.6
6
11
22
36
DC-link voltage (up to 2000 m above sea level)
V
DC
510 … 720
DC-link capacitance
μF
110
110
110
220
705
Overvoltage trip
Undervoltage trip
2)
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics power supply
V
DC
24 (20.4 … 28.8)
Electronics current drawn
at 24 VDC
A
DC
0.85
0.85
0.85
0.85
0.8
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
A
DC
A
DC
A
DC
100
150
20
Unit rating
3)
Based on I
n
(600 VDC; 4 kHz)
Based on I
H
kW
kW
1.6
1.4
2.7
2.3
4.8
4.1
9.7
8.2
16
13.7
Total power loss
(including electronics losses, see Power loss
tables (Page 756))
W 50.4 73.4 100.4 185.4 309.2
Max. pulse frequency
without derating
with derating
kHz
kHz
4
16
Output frequency
Hz 0 … 550
Sound pressure level
dB(A)
< 60
< 60
< 60
< 60
< 60
Cooling method
Internal fan
Cooling air requirement
m
3
/h
29.6
29.6
29.6
29.6
56
Max. permissible heat sink temperature
° C
75
75
79
82
85
Ventilation clearances
above/below
mm
80
Weight
kg
5
5
5
5
6.9
1)
Applies only to Article numbers with "." = 0 ... 3
2)
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the parame-
terized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC.