EasyManua.ls Logo

Siemens SINAMICS S120

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cabinet design and EMC Booksize
12.7 Connection systems
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
723
12.7.6.2
Attaching the motor connector to self-fabricated cables
Preparing the power cable
Non-assembled power cables must be appropriately prepared before the motor connector is
connected.
1. Remove the cable sheath to 200 mm ± 5 mm.
2. Fix the braided shield, e.g. with heat-shrink tubing
3. Remove the insulation from the individual U, V, W conductors and the motor holding
brake connecting cables and shorten these corresponding to the drawing shown below.
4. Remove the insulation from the single PE conductor, and crimp this with a ring cable lug
without insulation (Page 732).
Crimped with ring cable lugs without insulation
Crimped with conductor end sleeves according to DIN 46228-A1.5-10
Crimped with conductor end sleeves according to DIN 46228-E(1.5...10)-12
a, b, c, d
Lengths depend on mounting a shield connection plate (see below)
e
Length is dependent on the cable cross-section (see ring cable lug (Page 732))
Figure 12-30 Recommended stripped cable lengths for self-fabricated motor power cables, all data
in mm and (inches)
Shield support
The following options are available for cable shield support:
Shield support with shield plate supplied
Shield support on a toothed rail
Fixing your own shield support at the shield connection of the motor connector