Loading...
DC link components
8.3 Braking Module Booksize Compact
Booksize Power Units
510 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
8.3.5
Meaning of LEDs
Table 8- 13 Meaning of LEDs on the Braking Module Booksize Compact
LED
Color
Status
Description
Remedy
READY - Off The electronics power supply is missing or outside the
permissible tolerance range.
Check the electronics power
supply.
Green Continuous
light
The component is ready for operation. -
Red Continuous
light
Enable missing (input terminal)
Overtemperature of IGBT/braking resistor
Overcurrent trip
I
2
t monitoring activated
Braking power monitoring triggered
Ground fault/short circuit
Comment:
In the event of overtemperature, l
2
t monitoring or
braking power monitoring, the fault will be acknowl-
edged automatically after a cooling down phase.
Manual acknowledgment is not possible.
Troubleshoot the fault using
the output terminals and
acknowledge it using the
input terminal.
DC LINK - Off The DC link voltage is not available, the electronics
power supply is missing or is outside the permissible
tolerance range.
The component is not active.
Orange Continuous
light
The DC link voltage is present. -
Orange Flashing
light
The component is active. The DC link is being dis-
charged via the braking resistor.
-

Table of Contents