Line Modules Booksize
4.11 Smart Line Modules with cold plate
Booksize Power Units
322 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
4.11.8
Mounting
Please note the following before mounting a Smart Line Module with cold plate on a
customer-specific heat sink:
Before mounting, check the surface of the heat sink to ensure that it is not damaged.
To improve heat transfer, a heat-conducting medium must be used. Special spherical-
indented heat-conducting foil must be used for this purpose. Every cold plate power unit
is supplied with heat-conducting foil cut to the right size. Note the mounting position of the
heat-conducting foil (see figures below).
Note
Use heat conducting foil
Also replace the heat-conducting foil when replacing a component.
Only use heat-conducting foil released or supplied by Siemens.
Article No.
Heat-conducting foil, 50 mm
6SL3162-6FB00-0AA0
Note
To mount
the components, M6 threaded bolts and hexagon nuts/grub screws ISO 7436-
M6x40
-14 H, property class 8.8 are recommended.