Cabinet design and EMC Booksize
12.7 Connection systems
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
713
Comparison of MOTION-CONNECT power cables
MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. MOTION-
CONNECT 800PLUS power cables fulfill all of the high mechanical requirements for use in
tow chains. They are resistant to cutting oils.
Table 12- 16 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables
VDE
1)
cURus or UR/CSA
2)
Yes
Yes
Yes
Yes
0
/V in accordance with EN 50395
Supply conductors
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
Supply conductors
4 kV
4 kV
Operating temperature at the surface
Permanently installed
-20 … +80 °C
-50 … +80 °C
Permanently installed
50 N/mm
2
2
50 N/mm
2
2
Permanently installed
5 x D
max
4 x D
max
30 m/min Up to 300 m/min
2
2
3)
CFC/silicon-free CFC/halogen/silicon-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
EN 60811-2-1
PVC
DESINA color, orange RAL 2003
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color, orange, RAL 2003
The registration number is printed on the cable jacket.
The UR/CSA file number is stamped on the cable sheath.
Characteristic curves for accelerating can be found in Catalog "PM21" in Chapter "MOTION-CONNECT connection