Loading...
Accessories
11.4 DC link rectifier adapter for Booksize format
Booksize Power Units
632 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
11.4.5
Mounting
WARNING
Danger to life through electric shock if the cutout in the protective cover has been broken
out
Live components are open and accessible if the 24 V terminal adapter or the DC link infeed
adapter are removed. Touching live components can result in death or severe injury.
Replace the protective cover with the broken out cutouts by a new protective cover.
11.4.5.1
Installation on components that are 50 mm and 100 mm wide
Required tools:
Slot-head screwdriver (1 x 5.5) for releasing the protective cover
Torx T10 screwdriver to fasten the 24 V terminal adapter
Torx screwdriver T20 for DC link screws (Torx slot)
Pliers for breaking out the cutouts
Table 11- 16 Removing the DC link busbars
1. Release and open the protective
cover.
2. Remove the upper left-hand screw
and the DC link bridge
3. Remove the lower left-hand screw
and the DC link bridge