Line Modules Booksize
4.6 Active Line Modules Liquid Cooled
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
221
Liquid Cooled
6SL3135-7TE31-2AA3
Rated power
kW
120
Electronics current drawn at 24 V DC
A
DC
1.8
Total power loss
(including electronics losses, see Power loss
tables (Page 756))
W 2243.2
DC link capacitance
:
Active Line Module
Drive line-up, max.
μF
μF
3995
20000
Power factor
cos φ
1
Circuit breaker
(IEC 60947 and UL) See Chapter Overcurrent protection using fuses and
circuit breakers (Page 51)
Rated short-circuit current SCCR
3)
kA
65
Max. total cable length
4)
See Chapter
Combination options, Line Modules with line
reactors and line filters (Page 135)
Rated flow rate
for water
at 70 kPa pressure drop (for other coolants,
see Cooling circuit and coolant properties
(Page 771)
l/min 8
Volume of liquid internal
ml
100
Max. coolant temperature
without derating
with derating
° C
° C
45
50
Max. permissible heat sink temperature
° C
80
Weight
kg 23
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V.
2)
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
3)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker and the Line
Module in the drive system.
4)
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module