EasyManua.ls Logo

Siemens SINAMICS S120 - Page 284

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Line Modules Booksize
4.9 Smart Line Modules with internal air cooling
Booksize Power Units
284 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Internal air cooling
6SL3130-
6AE15-0A..
6AE21-0A..
6TE21-6A..
6TE23-6A..
6TE25-5AA.
Rated power
kW
5
10
16
36
55
Cooling method
(internal air cool-
ing)
Internal fan
Sound pressure level
dB(A)
< 60
< 60
< 60
< 65
< 60
Cooling air requirement
m
3
/h
29.6
29.6
56
112
160
Max. permissible heat sink tem-
perature
° C 69
5)
73
5)
77 80 75
Rated voltage for rated data 3 AC 380 V
Weight
kg
4.7
4.8
7
10
17
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V.
2)
For 16 kW and 36 kW Smart Line Modules: Default for 400 V line supplies; undervoltage trip threshold is adjusted to the
parameterized rated voltage.
3)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker and the Line
Module in the drive system.
4)
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module
5)
Values cannot be read out by the system (STARTER).