Line Modules Booksize
4.10 Smart Line Modules with external air cooling
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
311
Internal air cooling
6SL3131
6AE15–0AA.
6AE21–0AA.
6TE21-6AA.
6TE23-6AA.
6TE25-5AA.
Rated power
kW
5
10
16
36
55
Current carrying capacity
DC link busbars
Reinforced DC link busbars
24 V DC busbars
A
DC
A
DC
A
DC
100
150
20
100
150
20
100
150
20
200
--
20
200
--
20
Electronics current drawn
at 24 V DC
A
DC
0.8
0.9
0.95
1.5
1.9
Total power loss
(incl. electronics losses)
internal
external
(see power loss tables
(Page 756))
W
W
W
79.2
41.2
38
141.6
66.6
75
187.8
64.8
123
406
116
290
665.6
185.6
480
DC link capacitance
Smart Line Module
Drive line-up, max.
μF
μF
220
6000
330
6000
705
20000
1410
20000
1880
20000
Power factor
cos φ
0.98
0.98
0.98
0.98
0.98
Circuit breaker
(IEC 60947 and UL)
See Chapter Overcurrent protection using fuses and circuit breakers
(Page 51)
Rated short-circuit current SCCR
3)
kA
65
65
65
65
65
Max. total cable length
4)
See Chapter Combination options, Line Modules with line reactors and
line filters (Page 135)
Sound pressure level
dB(A)
< 60
< 60
< 60
< 65
< 60
Cooling air requirement
m
3
/h
29.6
29.6
56
112
160
Max. permissible heat sink tem-
perature
° C 69
5)
73
5)
77 80 75
Rated voltage for rated data 3 AC 380 V
Weight
kg
5.3
5.4
8.8
13.8
18.5
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V.
2)
For 16 kW and 36 kW Smart Line Modules: Default for 400 V line supplies; undervoltage trip threshold is adjusted to the
parameterized rated voltage.
3)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker and the Line
Module in the drive system.
4)
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module
5)
Values cannot be read out by the system (STARTER).