Line Modules Booksize Compact
5.2 Smart Line Modules Booksize Compact
Booksize Power Units
344 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Smart Line Module Booksize Compact
Rated DC link current
at 600 V
DC link current
at 540 V
at DC 600 V; S6 duty (40 %)
at DC 600 V; peak current
A
DC
A
DC
A
DC
27
30
35
Current carrying capacity
DC link busbars
Reinforced DC link busbars
A
DC
A
DC
DC
100
150
Electronics current consumption
at 24 V DC
For internal air cooling
A
DC
0.95
Total power loss internal air cooling
(including electronics losses, see Power loss
W
187.8
Power loss distribution for cold plate
(including electronics losses)
Internal
W
56.6
Smart Line Module
μF
705
(IEC 60947 and UL) See Chapter Overcurrent protection using line fuses
and circuit breakers (Page 51)
Rated short-circuit current SCCR
3)
4)
See Chapter Combination options, Line Modules with
line reactors and line filters (Page 135)
Internal air cooling
Cooling air requirement
with internal air cooling
3
Max. permissible heat-sink temperature
The specified power ratings apply to the line voltage range from 380 V to 480 V.
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker – and the Line
Module in the drive system.
4)
Maximum total cable length = Σ motor cables, line feeder cable from line filter to the Line Module