EasyManua.ls Logo

Siemens SINAMICS S120 - Page 385

Siemens SINAMICS S120
826 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Modules Booksize
6.3 Motor Module with external air cooling
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
385
Table 6- 17 X1 motor connection and X11 brake connection for Single Motor Modules 45 A to 200 A
Terminal
Technical data
U2
45 ... 60 A:
Threaded bolts M6 / 6 Nm
1)
85 A:
Threaded bolts M8 / 13 Nm
1)
132 … 200 A:
Threaded bolts M8 / 13 Nm
1)
V2
W2
PE connection
45 ... 60 A:
Threaded bolts for motor cables: M6 / 6 Nm
1)
Threaded hole for PE: M6 / 6 Nm
1)
85 A:
Threaded bolts for motor cables: M8 / 13 Nm
1)
Threaded hole for PE: M6 / 6 Nm
1)
132 ... 200 A:
Threaded bolts for motor cables: M8 / 13 Nm
1)
Threaded hole for PE: M8 / 13 Nm
1)
+ (BR+)
X11 brake connector
2)
:
Supply voltage: 24 V DC ±10 %
Max. load current: 2 A
Minimum load current: 0.1 A
Type: Spring-loaded terminal 2 (Page 730)
The brake connector is part of the prefabricated cable.
- (BR-)
1)
For ring cable lugs without insulation (Page 732)
2)
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be in-
stalled externally.
Motor holding brake connection
To ensure reliable opening of the motor holding brake, it requires a 24 V ± 10% voltage
supply at the motor connection. It must be taken into account that voltage dips can occur
along the supply cable.
Use a Control Supply Module or a regulated DC power supply, whose setpoint is set to
26 V.
Use supply cables with a minimum cross-section of 1.5 mm² and a maximum length of
100 m.