System overview
2.5 System data
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
47
Table 2- 2 Modules
Line Modules in the booksize format
Max. permissible supply voltage
3 AC 480 V
Rated pulse frequency
(for Active Line Modules in booksize format only)
8 kHz
Motor Modules in the booksize format
DC link supply voltage
510 … 720 V DC
Rated pulse frequency 4 kHz
At higher pulse frequencies the corresponding characteristic
for current derating must be taken into consideration
Table 2- 3 Degree of protection / protection class
Degree of protection
IPXXB according to EN 60529, open type according to UL/CSA
Protection class
Power circuits
Electronic circuits
I (with protective conductor connection)
safety extra-low voltage PELV/SELV
Table 2- 4 Environmental conditions
Chemically active substances
Long-term storage
Class 1C2 according to EN 60721-3-1, in product packaging
1)
Transport
Klasse 2C2 gemäß EN 60721-3-2, in transport packaging
2)
Operation
Class 3C2 according to EN 60721-3-3
Biological environmental conditions
Long-term storage
Class 1B1 according to EN 60721-3-1, in product packaging
1)
Transport
Class 2B1 according to EN 60721-3-2, in transport packaging
2)
Operation
Class 3B1 according to EN 60721-3-3
Climatic environmental conditions
Long-term storage Class 1K4 according to EN 60721-3-1, in product packaging
1)
Temperature: -25 … +55 °C
Transport Class 2K4 according to EN 0721-3-2, in product packaging
2)
Temperature: -40 … +70 °C
Operation Class 3K3 according to EN 60721-3-3 with increased ruggedness with respect to
relative humidity
Temperature: 0 ... +40 °C without derating
> 40 ... +55 °C with reduction of the output current by 2.67 % pro °C
Relative humidity: 5 … 95 % no condensation (better than Class 3K3)
Oil mist, salt mist, ice formation, condensation, dripping water, spraying water,
splashing water and water jets are not permitted
Mechanical environmental conditions
Long-term storage
Class 1M2 according to EN 60721-3-1, in product packaging
1)
Transport
Class 2M3 according to EN 60721-3-2, in transport packaging
2)
Operation
Class 3M1 according to EN 60721-3-3
Vibration test in operation
According to IEC 60068-2-6 test Fc (sinusoidal)

Table of Contents