Accessories
11.3 Reinforced DC link busbars
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
623
Table 11- 12 Removing the DC link busbars
1. Remove the installed DC link bridges and busbars, start-
ing at the second component.
Do not remove the DC link bridge and the busbars of the
first component.
2. Loosen the screws and remove the installed DC link
bridge of the component.
3. Remove the DC link busbar of the component.
4. Release the screws and remove the DC link bridges and
busbars at all of the other components.
Result: View with the DC link busbars removed