Cabinet design and EMC Booksize
12.4 Arrangement of components and equipment
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
681
Variant 5b: Module width 200-300 mm, connected to the drive line-up from the left, standard DC-link
busbar
DC-link adapter 6SL3162-2BM01-0AA0 (4 hole)
Standard DC-link busbar (6 mm)
Connecting the DC-link adapter to the module using 2 M4x20 screws
Connecting the DC-link busbar to the module using 4 M4x20 screws
Washer
Figure 12-11 Variant 5b (representation from below)
Variant 6: Module width 200-300 mm, connected to the drive line-up from the right, standard DC-link
busbar
DC-link adapter 6SL3162-2BM01-0AA0 (4 hole)
Standard DC-link busbar (6 mm)
Connecting the DC-link adapter to the module using 4 M4x20 screws
Connecting the DC-link busbar to the module using 2 M4x20 screws
DC-link bridge
Figure 12-12 Variant 6 (representation from below)