Loading...
Cabinet design and EMC Booksize
12.12 Power losses of the components
Booksize Power Units
764 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Table 12- 41 Electronics losses for power units with cold plate
Component
Cold plate
Power loss [W]
Motor Modules Booksize
3 A
15.6
5 A 15.6
9 A
15.6
18 A
15.6
30 A
15.6
45 A
18.0
60 A
18.0
85 A
19.2
132 A
20.4
200 A
20.4
2x3 A
21.6
2x5 A
21.6
2x9 A
21.6
2x18 A
25.2
Motor Modules Booksize Compact
3 A
15.6
5 A
15.6
9 A
15.6
18 A
15.6
2x1.7 A
21.6
2x3 A
21.6
2x5 A 21.6
Active Line Modules
16 kW
20.4
36 kW
25.2
55 kW
27.6
80 kW
33.6
120 kW
43.2
Smart Line Module Booksize
5 kW
14.4
10 kW
16.8
Smart Line Module Booksize Compact
16 kW
20.4
Basic Line Modules
20 kW
21.6
40 kW
26.4
100 kW
38.4
Table 12- 42 Electronics losses for liquid-cooled power units
Component
Liquid cooled
Power loss [W]
Motor Module
200 A
20.4
Active Line Module
120 kW
43.2

Table of Contents