Requirement
Mount the output elements as close as possible to the motor bearing.
Optimum Unfavorable
D
)
D
)
Low stress on shafts and bearings High stress on shafts and bearings
Mount or remove the output elements (for example, couplings, gear wheels, and belt
pulleys) b
y using suitable devices only.
• Use the threaded hole in the shaft extension.
• If required, heat up the output elements before mounting or removing.
• When removing the output elements, use an intermediate disk to protect the centering in the
shaft extension.
â‘  Intermediate washer/disk
Figureî™ 5-5 Mounting and removing output elements
• If
necessary, completely balance the motor together with the output elements according to
ISOî™ 1940.
Not
e
Motor
s with feather key are half-key balanced. The motors have been balanced with half a
feather key.
Mounting
5.2î™ Motor
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 121

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals