Requirement
Mount the output elements as close as possible to the motor bearing.
Optimum Unfavorable
D
)
D
)
Low stress on shafts and bearings High stress on shafts and bearings
Mount or remove the output elements (for example, couplings, gear wheels, and belt
pulleys) b
y using suitable devices only.
Use the threaded hole in the shaft extension.
If required, heat up the output elements before mounting or removing.
When removing the output elements, use an intermediate disk to protect the centering in the
shaft extension.
Intermediate washer/disk
Figure5-5 Mounting and removing output elements
If
necessary, completely balance the motor together with the output elements according to
ISO1940.
Not
e
Motor
s with feather key are half-key balanced. The motors have been balanced with half a
feather key.