Procedure
1. Assemble the X124 plug to the converter.
2. Attach the cable to the plug as shown below:
9
9
9
9
Connecting to the 24VDC power supply
Connecting to the daisy-chained converter
More information
For more inf
ormation about cable requirements, see Section "Cables and connectors
(Page130)".
For more information about assembling cable terminals, see Section "Assembling the cable
lugs (Page880)".
Connecting
6.7Connecting the 24 V DC power supply
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
152 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB