Procedure
1. Assemble the X124 plug to the converter.
2. Attach the cable to the plug as shown below:
① Connecting to the 24VDC power supply
② Connecting to the daisy-chained converter
More information
For more inf
ormation about cable requirements, see Section "Cables and connectors
(Page130)".
For more information about assembling cable terminals, see Section "Assembling the cable
lugs (Page880)".
Connecting
6.7Connecting the 24 V DC power supply
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
152 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB