Description of function
You can de󹪝ne the following settings in the function view with the same name:
Limitation
Position limits
You can activate and con󹪝gure the software and hardware limit switches to limit the
traversing range.
Dynamic response limits
You can de󹪝ne the limitations of the traversing pro󹪝le by specifying the maximum
velocity, acceleration, deceleration, and jerk.
Homing
Homing establishes the reference of the position measurement in the converter to the
machine. You can select between two homing types:
Active homing
You can select from three active homing modes to traverse the axis to a home position.
The drive itself then controls and monitors the homing cycle. You can also decide whether
absolute encoder adjustment should be automatically performed after home position
approach.
Passive homing
You select the input terminal for direct measuring probe 1 in the function view. When the
measuring probe is detected, the di󹪜erence between the home position and the
determined measured value is corrected on-the-󹪞y.
Absolute encoder adjustment
Absolute encoders must be adjusted during commissioning. When the machine is
switched o󹪜, the position information of the encoder is retained. The absolute encoder is
therefore 󹪝rst adjusted to the home position, e.g. by jogging.
Position monitoring functions
Position/standstill monitoring
You specify the positioning window, positioning monitoring time, standstill window, and
standstill monitoring time. The drive sets the "Setpoint stationary" signal to 1 as soon as
the setpoint for the position within a positioning operation no longer changes. With this
signal, the drive starts to monitor the actual position value.
Following error monitoring
You specify the maximum following error for the actual position value. If this following
error is violated, the position control cancels the current positioning operation and
generates a fault message.
Direct setpoint speci󹪝cation (MDI)
The setpoints listed in the function view are entered via PLC communications. You check
these setpoints in the function view for diagnostic purposes.
Traversing blocks
You can de󹪝ne a maximum of 32 traversing blocks in a con󹪝guration table in the function
view. For each traversing block, you de󹪝ne the required settings (Page383)and make 󹪝xed
stop con󹪝guration. An external control can subsequently select a traversing block that has
been selected.
Commissioning (Startdrive)
8.7Con󹪝guring the con
verter
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 281

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals