EasyManuals Logo

Siemens SINAMICS SIMOTICS S200 PROFINET User Manual

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #435 background imageLoading...
Page #435 background image
Text of the message class Number ac‐
cording to
PR
OFIdrive
Diagnostics inter‐
face
Cause and remedy PN
(hex)
DS1
(dec)
Communication error t
o the higher-level controller
The communication to the higher
-level controller (internal cou‐
pling, PROFIBUS, PROFINET...) is faulted or interrupted.
Check the state of the higher-level control system.
Check the communication connection/wiring.
Check the bus con󹪝guration/clock cycles.
(9) 9008 8
Safety monitoring channel has identi󹪝ed an error
A safe oper
ation monitoring function (Safety) has detected an
error.
(10) 9009 9
Actual position value/actual speed value incorrect or not
available
An
illegal signal state was detected while evaluating the encoder
signals (track signals, zero marks, absolute values…).
Check the encoder/status of the encoder signals.
Observe the maximum permissible frequencies.
(11) 900A 10
Internal (DRIVE-CLiQ) communication error
The internal
communication between the SINAMICS components
is faulted or interrupted.
Check the DRIVE-CLiQ wiring.
Ensure an EMC-compliant design.
Observe the maximum quantity structure/cycles.
(12) 900B 11
Infeed fault
The infeed is faulted or has failed.
Check the infeed and its environment (line supply, 󹪝lters, re‐
actors, fuses…).
Check the infeed control.
(13) 900C 12
Braking controller/Braking Module faulted
The internal
or external Braking Module is faulted or overloaded
(temperature).
Check the connection/state of the Braking Module.
Comply with the permissible number of braking operations
and their duration.
(14) 900D 13
Line 󹪝lter fault
ed
The line 󹪝lter monitoring has identi󹪝ed an excessively high tem‐
perature or other inadmissible state.
Check the temperature/temperature monitoring.
Check the con󹪝guration to ensure that it is permissible (󹪝lter
type, infeed, thresholds).
(15) 900E 14
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 433

Table of Contents

Questions and Answers: