133: Access method not de󹪝ned.
200: Below the v
alid values.
201: Above the valid values.
202: Cannot be accessed from the Basic Operator Panel (BOP).
203: Cannot be read from the Basic Operator Panel (BOP).
204: Write access not permitted.
Remedy: - Correct the parameterization in the commissioning tool and download the project again.
- Enter the cor
rect value in the speci󹪝ed parameter.
- Identify the parameter that restricts the limits of the speci󹪝ed parameter.
A01100 CU: Memory card withdrawn
Message class: General drive fault (19)
Message value: -
Component: Control Unit (CU)
Response: NONE
Acknowledgment: NONE
Cause: The memory card (non-volatile memory) was withdrawn during operation.
No
tice:
It is not permis
sible for the memory card to be withdrawn or inserted under voltage.
Remedy: - Switch o󹪜 the driv
e system.
- Re-insert the memory card that was withdrawn - This card must match the drive system.
- Switch on the drive system again.
F01105 CU: Insu󹪟cient memory
Messag
e class: Error in the parameterization / con󹪝guration / commissioning pr
ocedure (18)
Message value: %1
Component: Control Unit (CU)
Response: OFF1
Acknowledgment: POWER ON
Cause: The functionality on this Control Unit is too extensive (e.g. too many drives, functions, data sets, Technology Extensions,
bloc
ks, e
tc).
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy: - Change the con󹪝guration on this Contr
ol Unit, e.g.
-- Use fewer axes
-- Reduce the number of con󹪝gurable functions
-- Use fewer data sets
-- Reduce Technology Extensions and blocks
- Use an additional Control Unit.
F01107 CU: Save to memory card unsuccessful
Message class: Hardware/software error (1)
Message value: %1
Component: Control Unit (CU)
Response: NONE
Acknowledgment: IMMEDIATELY
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 451

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals