Component: None
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: After the active homing starts, the axis moved through the maximum permissible distance to search for the reference cam
wit
hout actually
nding the reference cam.
Remedy: - Check signal "Reference cam" (c2612).
- Check the maximum permis
sible distance to the reference cam (p2606).
- If axis does not have any reference cam, then set p2607 to 0.
See also: p2606 (EPOS active homing reference cam maximum distance), p2607 (EPOS active homing reference cam
available), c2612 (EPOS active homing reference cam)
F07459 EPOS: No zero mark
Message class: Application/technological function faulted (17)
Message value: -
Component: None
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: After leaving the reference cam, the axis has traversed the maximum permissible distance between the reference cam and
zer
o mar
k wit
hout nding the zero mark.
Remedy: - Check the encoder regarding the zero mark.
- Check the maximum permis
sible distance between the reference cam and zero mark (p2609).
- use an external encoder zero mark (equivalent zero mark) (p0494).
See also: p2609 (EPOS active homing max distance reference cam and zero mark)
F07460 EPOS: End of reference cam not found
Message class: Application/technological function faulted (17)
Message value: -
Component: None
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: In the "active homing" mode, when approaching the zero mark, the axis reached the end of the traversing range without
de
tecting an edge at binary signal "Reference cam" (c2612).
Maximum traversing range: -2147483648 [LU] ... -2147483647 [LU]
Remedy: - Check signal "reference cam" (c2612).
- Repeat active homing.
See also: c2612 (EPOS active homing r
eference cam)
A07461 EPOS: Home position not set
Message class: Application/technological function faulted (17)
Message value: -
Component: None
Response: NONE
Acknowledgment: NONE
Cause: When starting a traversing block/direct setpoint input, a home position is not set (r2684.11 = 0).
Remedy: Carry out homing (active homing, passive homing, set home position).
A07462 EPOS: Selected traversing block number does not exist
Message class: Error in the parameterization / conguration / commissioning pr
ocedure (18)
Message value: %1
Component: None
System messages
12.3Faults and alarms