Component: Motor
Response: NONE
Acknowledgment: NONE
Cause: The torque deviates from the torque/speed envelope characteristic (too high).
Remedy: - Check the connection between the motor and load.
- A
dapt t
he parameterization corresponding to the load.
A07922 Drive: Torque/speed out of tolerance
Message class: Application/technological function faulted (17)
Message value: -
Component: Motor
Response: NONE
Acknowledgment: NONE
Cause: The torque deviates from the torque/speed envelope characteristic.
Remedy: - Check the connection between the motor and load.
- A
dapt t
he parameterization corresponding to the load.
F07923 Drive: Torque/speed too low
Message class: Application/technological function faulted (17)
Message value: -
Component: Motor
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The torque deviates from the torque/speed envelope characteristic (too low).
Remedy: - Check the connection between the motor and load.
- A
dapt t
he parameterization corresponding to the load.
F07924 Drive: Torque/speed too high
Message class: Application/technological function faulted (17)
Message value: -
Component: Motor
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The torque deviates from the torque/speed envelope characteristic (too high).
Remedy: - Check the connection between the motor and load.
- A
dapt t
he parameterization corresponding to the load.
F07925 Drive: Torque/speed out of tolerance
Message class: Application/technological function faulted (17)
Message value: -
Component: Motor
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The torque deviates from the torque/speed envelope characteristic.
Remedy: - Check the connection between the motor and load.
- A
dapt the parameterization corresponding to the load.
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
534 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB