Cause: An internal error has occurred in the Safety Integrated software.
Note:
This mes
sage results in an STO (Safe Torque O󹪜) that cannot be acknowledged.
Message value (r60049, interpret hexadecimal):
Only for internal Siemens troubleshooting.
Remedy: - Carry out a POWER ON (switch-o󹪜/switch-on) f
or all components.
- Re-commission the "Safety Integrated" function and carry out a POWER ON.
- Upgrade 󹪝rmware to later version.
- Contact Technical Support.
- Replace hardware component.
N30800 Power unit: Group signal
Message class: Power electronics faulted (5)
Message value: -
Component: Power Unit
Response: OFF2
Acknowledgment: NONE
Cause: The power unit has detected at least one fault.
Remedy: Evaluate the other messages that are presently available.
F30801 Power unit: Sign-of-life missing
Message class: Internal (DRIVE-CLiQ) communication error (12)
Message value: Component number: %1, fault cause: %2
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: Internal communications error.
The com
puting time load might be too high.
Mes
sage value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
xx = 0A hex (10 dec):
The sign-of-life bit in the receive telegram is not set.
Remedy: - Deselect functions that are not required.
F30802 Power unit: Time slice over󹪞o
w
Message class: Hardware/software error (1)
Message value: %1
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: A time slice o
ver󹪞o
w has occurred.
Fault value (r0949, interpret decimal):
xx: time slice number
Remedy: - Carry out a POWER ON (switch-o󹪜/switch-on) f
or all components.
- Upgrade 󹪝rmware to later version.
- Contact Technical Support.
F30804 Power unit: Checksum error occurred
Message class: Hardware/software error (1)
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 567