Message value: %1
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: A checksum error (CRC error) has occurred for the power unit.
Remedy: - Carry out a POWER ON (switc
h-o/switch-on) f
or all components.
- Upgrade rmware to later version.
- Contact Technical Support.
F30805 Power unit: EEPROM checksum error
Message class: Hardware/software error (1)
Message value: %1
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: Internal parameter data is corrupted.
F
ault value (r0949, int
erpret hexadecimal):
01: EEPROM access error.
02: Too many blocks in the EEPROM.
Remedy: Replace the module.
F30809 Power unit: Switching information not valid
Message class: Hardware/software error (1)
Message value: -
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: For 3P gating unit, the following applies:
The las
t switching s
tatus word in the setpoint telegram is identied by the end ID. Such an end ID was not found.
Remedy: - Carry out a POWER ON (switch-o/switch-on) f
or all components.
- Upgrade rmware to later version.
- Contact Technical Support.
F30810 Power unit: Watchdog timer expired
Message class: Hardware/software error (1)
Message value: -
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: The watchdog timer has expired. This can only be caused by a fatal software error.
Remedy: - Carry out a POWER ON (switc
h-o/switc
h-on) f
or all components.
- Upgrade rmware to later version.
- Contact Technical Support.
F30815 Power unit: Processor clock signal error
Message class: Hardware/software error (1)
Message value: -
Component: Power Unit
Response: OFF2
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2