Acknowledgment: IMMEDIATELY
Cause: Communications error.
Er
ror cause:
11 (= 0B he
x):
Synchronization error during alternating cyclic data transfer.
Note regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
Remedy: Carry out a POWER ON (switch-o/switch-on).
F30896
Power unit (CU): Inconsistent component properties
Message class: Internal (DRIVE-CLiQ) communication error (12)
Message value: Component number: %1
Component: Power Unit
Response: OFF2
Acknowledgment: IMMEDIATELY
Explanation of the
mes
sag
e v
alue:
For %1
Component in target topology
Cause: The properties of the component (power unit), specied
by
the fault value, have changed in an incompatible fashion with
respect to the properties when running up.
Fault value (r0949, interpret decimal):
Component number.
Remedy: - Carry out a POWER ON.
F30899 Power unit: Unknown fault
Message class: Power electronics faulted (5)
Message value: New message: %1
Component: Power Unit
Response: NONE
Acknowledgment: IMMEDIATELY
Cause: A fault occurred on the power unit, which cannot be interpreted by the converter rm
ware.
This can occur if the rmware on this component is more recent than the converter rmware.
Fault value (r0949, interpret decimal):
Fault number.
Note:
If required, the signicance of this new fault can be read about in a more recent description of the converter.
Remedy: - Replace the rmwar
e on the power unit by an older rmware version.
- Upgrade the converter rmware.
F30903 Power unit: I2C bus error occurred
Message class: Hardware/software error (1)
Message value: %1
Component: Power Unit
Response: NONE
Acknowledgment: IMMEDIATELY
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
574 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB