Acknowledgment: NONE
Cause: Error when operating the internal SPI bus.
Alarm v
alue (r2124, interpr
et hexadecimal):
Only for internal Siemens troubleshooting.
Remedy: - Replace the Sensor Module.
- If requir
ed, upgrade the 󹪝rmware in the Sensor Module.
- Contact Technical Support.
A31903 Motor encoder: I2C-BUS error occurred
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: NONE
Acknowledgment: NONE
Cause: Error when operating the internal I2C bus.
Alarm value (r2124, int
erpr
e
t hexadecimal):
Only for internal Siemens troubleshooting.
Remedy: - Replace the Sensor Module.
- If requir
ed, upgrade the 󹪝rmware in the Sensor Module.
- Contact Technical Support.
F31905 Motor encoder: Encoder parameterization error
Message class: Error in the parameterization / con󹪝gur
ation / commis
sioning pr
ocedure (18)
Message value: Parameter: %1, supplementary information: %2
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: IMMEDIATELY
Cause: An error was identi󹪝ed in t
he encoder parame
terization.
It is possible that the parameterized encoder type does not match the connected encoder.
Determine the parameter number using the fault value (r0949).
Fault value (r0949, interpret decimal):
yyyyxxxx dec: yyyy = supplementary information, xxxx = parameter
yyyy = 0:
No additional information available.
yyyy = 10:
The connected encoder is not supported.
Remedy: - Check whether the connected encoder type matches the encoder that has been parameterized.
- Correct t
he parameter speci󹪝ed by the fault value (r0949).
F31950 Motor encoder: Internal software error
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: POWER ON
Cause: An internal software error has occurred.
F
ault value (r0949, int
erpret decimal):
The fault value contains information regarding the fault source.
Only for internal Siemens troubleshooting.
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
582 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals