Technical data
14
14.1 Technical data of the converter
14.1.1
Permis
sible environmental conditions for the converter
Technical data
Table 14-1 Environmental conditions
Property Description
Environmental conditions for transport in the transport packaging
Climatic environmental conditions
• Surrounding air temperature: -40 °C ... +70°C
Suitable according t
o Class 2K4 to IEC60721‑3‑2
• Humidity: Max. 95% at 45°C according to IEC60721‑3‑2
Mechanical environmental conditions Vibration:
• 2Hz...9Hz: 7.5mm deection
• 9Hz...200Hz: 2g vibr
ation
Vibrations permissible according to Class 2M3 to IEC60721-3-2
Protection against chemical substances Protected according to Class 2C2 to IEC60721-3-2
Biological environmental conditions Suitable according to Class 2B2 to IEC60721-3-2
Environmental conditions for long-term storage in the product packaging
Climatic environmental conditions
• Surrounding air temperature: -40°C ... +70°C
•
Relativ
e humidity
: Max. 95%, condensation not permissible
Mechanical environmental conditions Vibrations permissible according to Class 1M2 to IEC60721-3-1
Protection against chemical substances Protected according to Class 1C2 to IEC60721-3-1
Biological environmental conditions Suitable according to Class 1B2 to IEC60721-3-1
Environmental conditions in operation
Installation altitude
• Up to 2000 m above sea level without power derating
•
Up t
o 4000m with power derating
Climatic environmental conditions
• Surrounding air temperature: 0°C ... 55°C, > 45°C with power
derating
• Relativ
e humidity: Max. 95%, condensation not permissible
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 609