14.2.11.2 Permissible radial forces
Description
As a result of the bearing arrangement, the 1FL2 is designed for aligned forces. Forces such as
these occur for belt drives, for example.
All radial forces always refer to aligned forces.
NOTICE
Motor damage caused by circulating forces
Circulating for
ces can cause bearing motion, and therefore damage the motor.
Avoid rotating forces.
5
[
)
F
R
Point of application of the radial force
x Distance between where the radial force is applied and the shaft shoulder in mm
Figure14-6 Point of application of radial forces F
R
at the shaft e
xtension
The following diagrams indicate the maximum permissible radial force for the corresponding
motor fr
ame size. It depends on the force application point and the average speed for a
nominal bearing service life (L10h) of 20000 h.











)51
[PP
Q UPLQ
Q UPLQ
Q UPLQ
Q UPLQ
Q UPLQ
Q UPLQ
)/)5
/
K K
Figure14-7 Radial force diagram 1FL2102
Technical data
14.2Technical data of the motor
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
636 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB