EasyManuals Logo

Siemens SINAMICS SIMOTICS S200 PROFINET User Manual

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #692 background imageLoading...
Page #692 background image
Action: EMERGENCY OFF EMERGENCY STOP
Stop category0 according to IEC60204‑1
Solution with the STO Safety
Int
egr
ated function integra‐
ted into the drive:
STO is not suitable for switching o󹪜 an elec‐
trical voltage.
Select STO:
.
It is permissible that you also switch o󹪜 the con‐
ver
ter supply voltage. However, switching o󹪜 the
voltage is not required as a risk reduction meas‐
ure.
Appendix
A.2EMERGENCY OFF and EMERGENCY STOP
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
690 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB