p0219[0...1] Braking resistor braking power
Data type: FloatingPoint32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Dynamic braking, Quick commissioning
Unit: kW
Min:
0.00 [kW]
Max:
20000.00 [kW]
Factory setting:
0.00 [kW]
Description: Sets the braking power of the connected braking resistor.
Index: [0] = Maximum power
[1] = R
at
ed po
wer
r0277[0] Power unit heat sink fan wear counter
Data type: FloatingPoint32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: Power unit
Unit: %
Description: Displays the wear counter of the heat sink fan in the power unit.
After a fan has been r
eplaced, using an appropriate button, the value can be reset in the commissioning tool to 0.
Dependency: See also: A30042
p0290 Power unit overload response
Data type: Integer16 V
isible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Ready for operation
Parameter group: Power unit
Unit: -
Min:
0
Max:
1
Factory setting:
0
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
708 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB