p9729 SI reference checksum conguration of the saf
ety functions
S200 PN Data type: Unsigned32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tat
e:
Commissioning (Safety Integrated)
Parameter group: Extended functions
Unit: -
Min:
0000 he
x
Max:
FFFF FFFF hex
Fact
ory setting:
A1A1 A1A1 hex
Description: Sets the checksum over the checked parameters used to congure safe
ty functions (reference checksum).
Dependency: See also: r9728
r9750[0...63].0...20 SI diagnostic attributes
Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: Extended functions
Unit: -
Description: Displays the diagnostic attributes of the safety messages that have occurred.
Bit array: Bit Signal name 1 signal 0 signal
00 Hardware replacement recommended Yes No
15 Message has gone Yes No
16 PROFIdrive fault class bit 0 High Low
17 PROFIdrive fault class bit 1 High Low
18 PROFIdrive fault class bit 2 High Low
19 PROFIdrive fault class bit 3 High Low
20 PROFIdrive fault class bit 4 High Low
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 857