r9722.0...7 SI status signals
S200 PN Data type: Unsigned32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: Extended functions
Unit: -
Description: Display and signal source for the status signals for the safety functions (synchronized signal).
Bit array: Bit Signal name 1 signal 0 signal
00 STO or safe pulse cancellation active Yes No
07 Internal event No Yes
NOTICE
For bit 07:
An int
ernal ev
ent is displayed if a stop function is active.
r9725[0...2] SI diagnostics data cross-check
S200 PN Data type: U
nsigned32 V
isible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: Extended functions
Unit: -
Description: Displays the diagnostics of the data cross-check.
For index [0]
N
umber of the data, which, for the data cross-check between the two monitoring channels, led to the SCF (Safety
Channel Failure) on the drive.
For index [1]:
Displays the value from channel A for a KDV error.
For index [2]:
Displays the value from channel B for a KDV error.
Index: [0] = Message value for KDV
[1] = KDV actual value c
hannel A
[2] = KDV actual value channel B
Note
KDV: Dat
a cross-check
r9728 SI actual checksum congur
ation of t
he saf
ety functions
S200 PN Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: Extended functions
Unit: -
Description: Displays the checksum over the checked parameters used to congure safe
ty functions (actual checksum).
Dependency: See also: p9729