EasyManua.ls Logo

Siemens SINAMICS SIMOTICS S200 PROFINET - Page 862

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index: [0] = SI checksum to track functional changes
[1] = SI check
sum to track hardware-speci󹪝c changes
Dependency: See also: p9729
r9781[0...1] SI change control time stamp days
S200 PN Data type: Unsigned16 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Safety Integrated
Unit: -
Description: Displays the day component of the time stamp for the checksums for tracking changes for Safety Integrated.
The time stam
ps are generated for the checksums (r9780[0...1]) (󹪝ngerprint for the "safety logbook" functionality)
Index: [0] = SI time stamp for checksum to track functional changes
[1] = SI time stam
p for checksum to track hardware-speci󹪝c changes
Dependency: See also: p9729, p9799
Note
The time comprises r9781 (da
ys) and r9782 (milliseconds).
r9782[0...1] SI change control time stamp milliseconds
S200 PN Data type: Unsigned32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Safety Integrated
Unit: ms
Description: Displays the millisecond component of the time stamp for the checksums for tracking changes for Safety Integrated.
The time stam
ps are generated for the checksums (r9780[0...1]) (󹪝ngerprint for the "safety logbook" functionality)
Index: [0] = SI time stamp for checksum to track functional changes
[1] = SI time stam
p for checksum to track hardware-speci󹪝c changes
Dependency: See also: p9729, p9799
Note
The time comprises r9781 (da
ys) and r9782 (milliseconds).
r9794 SI actual checksum safety enable
S200 PN Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Basic functions
Unit: -
Description: Displays the checksum over the parameters to enable the safety functions (actual checksum).
Dependency: See also: p9795
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
860 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Related product manuals