The standard ‘trap’ objects that are available for the C10 HD system in V1.1/5 software are shown in the following table.
!-50.? =:8 0>.=4;?4:9
sslC10Restarting
System System restarting
sslC10MemLow
System Blackrock DSP card memory low
sslC10DspReboot
System A DSP device on the Blackrock DSP card has rebooted
sslC10DspRebootFail
System
A DSP device on the Blackrock DSP card has failed to
reboot
sslC10Psu1Fail
Processor Blackrock processor PSU 1 failure
sslC10Psu2Fail
Processor Blackrock processor PSU 2 failure
sslC10MainGfx1Fail
Console Primary console TFT meter driver failure
sslC10MainGfx2Fail
Console Secondary console TFT meter driver failure
sslC10LostTileComms
System Lost Ethernet communication to the control surface
sslC10ResumedTileComms
System
Recovered Ethernet communication with the control
surface
sslC10Synclost
System External (Video/AES) sync lost
sslC10SyncReturned
System External (Video/AES) sync recovered
sslC10NowActiveInRedundantPair
System
Blackrock processor is now the active member of a
redundant pair
sslC10NowDormantInRedundantPair
System
Blackrock processor is now the dormant member of a
redundant pair
sslC10DiskStatusNotify
SBC
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
sslC10RaidStatusNotify
SBC
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
C10 HD Installation Manual Section 6: Appendices | Page 6-29
K: SNMP