The individual SNMP objects for B-RIO units that are exported from V1.1/5 software are as follows:
$!% "&$"%
The standard ‘trap’ objects that are available for B-RIO units in V1.1/5 software are as followings:
'$&$  !$&! ! % "
A great deal of information regarding SNMP is of course available from the internet whilst a highly recommended book is
‘>>09?4,7% "9/0/4?4:9’, published by !I$0477D0/4, (ISBN10:
0-596-00840-6
, ISBN13:
9780596008406
).
!-50.? =:8 0>.=4;?4:9
sslRioOnline
B-RIO A B-RIO unit has come online
sslRioOffline
B-RIO A B-RIO unit has gone offline
sslRioChassisFan1Fail
B-RIO B-RIO chassis fan 1 failure
sslRioChassisFan2Fail
B-RIO B-RIO chassis fan 2 failure
sslRioPsu1Fail
B-RIO B-RIO PSU 1 failure
sslRioPsu2Fail
B-RIO B-RIO PSU 2 failure
sslRioPsu1FanFail
B-RIO B-RIO PSU 1 fan failure
sslRioPsu2FanFail
B-RIO B-RIO PSU 2 fan failure
!-50.? &D;0 0>.=4;?4:9
sslRioIndex
read-only
The index of the B-RIO unit – up to 8 units may be
connected and addressed
s
slRioPresent
read-only Indicates if a B-RIO unit is connected to the system
s
slRioVersion
r
ead-only
C
arries the B-RIO firmware version string
sslRioTemp1
read-only
Temperature reading in degrees Celcius from the primary
internal temperature sensor
sslRioTemp2
read-only
Temperature reading in degrees Celcius from secondary
internal temperature sensor
sslRio1v2
read-only Voltage reading from the +1.2V rail
sslRio3v3r1
read-only Voltage reading from the +3V3 rail (primary sensor)
sslRio3v3r2
read-only Voltage reading from the +3V3 rail (secondary sensor)
sslRio5v
read-only Voltage reading from the +5V rail
sslRio5v5
read-only Voltage reading from the +5V5 rail
sslRio15V
read-only Voltage reading from the +15V rail
sslRioMinus15V
read-only Voltage reading from the –15V rail
sslRioCardsInfo
read-only
A string providing details of which I/O cards are currently
fitted to this B-RIO
sslC10NowDormantInRedundantPair
System
Blackrock processor is now the dormant member of a
redundant pair
sslC10DiskStatusNotify
SBC
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
sslC10RaidStatusNotify
SBC
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
Page 6-30 | Section 6: Appendices C10 HD Installation Manual
K: SNMP