Chapter 4
Troubleshooting
P/N 79000035_SM, Version 1.5 4 - 41 Focus 30/35 Service Manual
11 Subsystem error drives
Drive system not initialied 2
3 6 B D D1
FI: 10 Code: 0xf005
Message:
3|0|99|0|1104500|PositionHV
faile
FI: 10 Code: 0x9c52
Message: Req x6e got res 9
FI: 1 Code: 0x9c4e Message:
Drive system: Not initialized
( 2 3 6 B D
Check Fine drive vertical
Exchange the Fine drive
vertical
12 V knob: no movement
Drive System: error message
warning 6
Drive System: turn event
error warning 6 B D D1
FI: 10 Code: 0xf001
Message: Axis: 1 B1: 0 B2: 1
LB blocke
FI: 10 Code: 0xf005
Message: 2|0|99|-
100|8600|PositionHV faile
FI: 10 Code: 0x9c52
Message: Req x6e got res 9
Knobs Error: 0xf001
(61441)///drives V: Error:
0xf001 (61441)
Check the Solenoid V
Exchange the Coarse drive V
13 Drive System :Turn event
error warning 6 B D1 C C1
FI: 10 Code: 0xf005
Message: 3|0|99|100|-
126229100|PositionHV faile
FI: 0 Code: 0x9c5d Message:
SNPInCompletionCallback
Status: 262
Check Coarse drive motor V
Exchange the Coarse drive V
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation