Event Code Message Text and Description Details and Solution
2035
Initialization failure due to
robot gripper positioning
error.
Check for obstructions in the gripper
pathway of the robot such as a
cartridge sitting in the shuttle of the
robot.
2036
Unintended termination of
application process.
Reboot or power cycle system.
2037
Robotic firmware version
upgrade failed.
Reboot or power cycle system. If the
problem persists, contact Spectra
Logic Technical Support. See
Contacting Spectra Logic on pageî ±11.
2038
Lost connection to Module. Ensure that all modules are powered
and have the interconnect cable
properly attached. Reboot or power
cycle the system.
2039
Cartridge left in robot gripper,
unable to be moved to any
open location.
Enable EE ports and ensure that
some of them are free. Then power
cycle library. If still failing, open
covers and remove cartridge
manually from gripper.
2040
Wellness test failed with
critical error.
See codes 2041-2051.
2041
Wellness test failed because of
unit lock failed.
Ensure that the alignment
mechanism is engaged in every
module that is above another module
in the library
2042
Wellness test failed because of
top cover is missing.
Install the top cover on the top
module of the library. Also check the
module interconnect cabling and
module power cabling. If the
controller module cannot detect both
a top and bottom cover the robot will
not move.