Event Code Message Text and Description Details and Solution
2062
Move failed inserting
cartridge to drive.
Check for labels or cartridge
misalignments that would prevent
the cartridge from coming out of the
drive.
2063
Move failed positioning picker
in front of drive.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
2064
Library test failed with critical
error.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
2065
Library startup process failed
because of robotics
initialization issue.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
2066
Library startup process failed
during inventory scan.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
2067
For safety reason the robot
movement was halted in
place.
Ensure that all magazines, top or
bottom covers and unit locks are
completely inserted and properly
locked. Do not open magazines using
the emergency release or remove
covers or unit locks while the library
is operating and the robot is moving.
Ensure that all modules are powered
and have the interconnect cable
properly attached.
2068
An emergency stop condition
was detected in one or more
modules and prevented the
robotic assembly from
initialization.
Ensure that all magazines, top or
bottom covers and unit locks are
completely inserted and properly
locked. Please insert all open
magazines and install all necessary
covers and unit locks before
powering on the library. Ensure that
all modules are powered and have
the interconnect cable properly
attached.
JANUARY 2023 238
SPECTRA STACK LIBRARY
USER GUIDE