6-19
Service mode Service settings
[CONFIDENTIAL]
Maintenance
Contents
Counter reset for the maintenance kit.
The "Install MK" message means that maintenance kit should be replaced at fixed pages of printing. The
interval counter must be manually reset using this service item.
Maintenance kit
MK-3260/3261/3262/3264 (45 ppm) :300,000 images
MK-3300/3301/3302/3304 (60/55/50 ppm) :500,000 images
Maintenance kit includes the following units:
• Drum unit
Developer unit
Transfer roller assembly
Fuser unit
Paper feed roller assembly
Retard roller assembly
Purpose
To reset the life counter for maintenance kit.
Method
Drum unit
Developer unit
Transfer roller assembly
Fuser unit
Paper feed roller assembly
Retard roller assembly
Method
1 Enter the Service Setting menu.
2 Select [Maintenance] using the [▲][▼] keys.
3 Press the [OK] key.
4 Select the [YES] using the left select key.
5 [Accepted] is displayed and Test page will be printed.
Completion
Press the [Stop] key.
Important
Occurrences of resetting the maintenance kits are recorded on the service status page or event log in number
of pages at which the maintenance kit was replaced
(See page 6-3, 6-12). This may be used to determine the
possibility that the counter was errorneously or unintentionally reset.