Chapter 6 Installation and Initial Operation Alpha Compact 32708612
Version: 14.12.2012 page 75 of 135
Instructions
Please adjust the rotating angle at the swing arm as follows.
Step Procedure
1 Pull off the protective cap at the swing module.
2 Loosen the clamping screw to the 1. end position by means of a hexagon
socket wrench.
3
djust the end position so that the tamp is horizontally in home position and
that the tamp is 1-2 mm more deeply than the peeler bar.
4 Tighten again the 1. end position.
5 Loosen the 2. end position and adjust it so that the rotating tamp is parallel to
the product in extended position. If the labeler is operated in Tamp On Mode,
the tamp has to touch the product slightly. If the labeler is operated in Tamp
Blow Mode, the tamp may not touch the product.
6 Tighten again the 2. End position.