Maintenance
6606−1/A1
Winterthur Gas & Diesel Ltd.
17/ 17
3) Install the outlet pipes (6 and 9, Fig. 23).
4) Install the inlet pipes (3 and 11).
5) Open the butterfly valves (1 and 12, Fig. 1) of each SAC (5, 12).
6) Release the air in each SAC (5, 12).
7) Start the cooling water pump.
8) Make sure that there are no water leaks.
9) Make sure that no scavenge air flows between the SAC (5, 12) and the SAC
housings.
10) Stop the cooling water pump.
2015
Scavenge Air Cooler: Removal and Installation