Maintenance81551/A1
Winterthur Gas & Diesel Ltd.
10/ 10
3. Close Up
1) Make sure that the SCR valve (1) can move freely (refer to the documentation of
the valve supplier).
Note: For the applicable lubricants and the maintenance guidelines of the
cardan rod, refer to the documentation of the cardan rod supplier.
2) Apply applicable lubricant to the cardan rod.
3) Open the ball valve 508135_E0_3 (refer to Operation Manual 400310).
4) Start the control air supply (refer to the Operation Manual 46051).
5) Start the SCR system (refer to the Operation Manual 92701).
6) Start the automatic valve movement procedure to make sure that the SCR
valve (1) operates correctly (refer to the Operation Manual, 92701).
SCR Valve Removal and Installation
201611